MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds.They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.This type has also a clear and reliable indication of fault in a separate window in the event of short-circuittripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanismand a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- andsingle phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts,signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. Theseare suitable throughout the MS132-B/MS165-B range.– designed in accordance to the applicable parts of IEC 60077 standard– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)– usable according to European fire and smoke safety standard EN 45545-2
Spécifications techniques

Dimensions

Produit Largeur Net45 mm
Produit Hauteur Net90 mm
Produit Longueur Net86.75 mm
Poids net0.265 kg

Technique

Pourvoir assigné de coupure de service en court-circuit (Ics)(230 V AC) 100 kA, (250 V DC) 3 Poles in Series 10 kA, (400 V AC) 100 kA, (440 V AC) 30 kA, (500 V AC) 20 kA, (690 V AC) 3 kA
Pouvoir assigné de coupure ultime en court-circuit (Icu)(230 V AC) 100 kA, (400 V AC) 100 kA, (440 V AC) 30 kA, (500 V AC) 20 kA, (690 V AC) 3 kA
Courant assigné instantané de réglage de court-circuit (Ii)78.8 A
Setting Range4.0 ... 6.3 A
Puissance assignée d’emploi AC-3 (Pe)(400 V) Three Phase 2.2 kW
Puissance assignée d’emploi AC-3e (Pe)(400 V) Three Phase 2.2 kW
TensionCircuit principal 690 V AC, Circuit principal 250 V DC
Courant nominal de fonctionnement (Ie)6.3 A
Courant assignée d’emploi AC-3 (Ie)6.3 A
Courant assignée d’emploi AC-3e (Ie)6.3 A
Courant assignée d’emploi DC-5 (Ie)6.3 A
Fréquence assignée (f)Circuit principal 50 Hz, Circuit principal 60 Hz
Tension assignée de tenue aux chocs (Uimp)Circuit principal 6 kV
Tension assignée d’isolement (Ui)690 V
Power Lossat Rated Operating Conditions per Pole 0.7 ... 1.8 W
Nombre de pôles3
Courant thermique conventionnel à l’air libre (Ith)Main Circuit 6.3 A
Indice de protectionHousing IP20, Main Circuit Terminals IP10
Degré de pollution3
Electrical Durability50000 cycle
Durabilite mecanique100000 cycle
Type de borneBornes à vis
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm², Flexible 1/2x 0.75 ... 2.5 mm², Rigid 1/2x 1 ... 4 mm²
Couple de serrageMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Recommended Screw DriverPozidriv 2
Type d'encastrement1 ... 6
Montage sur rail DINTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 400 V 0 mm, Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm, Electrical Conductive Board, Vertical 75 mm, Other Device Same Type, Horizontal 0 mm, Other Device Same Type, Vertical 150 mm
Actuator TypePOIGNÉE ROTATIVE
Contact Position IndicationON / OFF / TRIP
Normes et standardsIEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1
RemarquesUL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx

Technique UL/CSA

Short-Circuit Current Rating (SCCR)Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA, Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 18 kA, Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA, Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA, Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA, Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA, Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA, Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Maximum Operating Voltage UL/CSACircuit principal 600 V AC
Puissance nominale UL/CSA(200 V AC) Three Phase 1 Hp, (208 V AC) Three Phase 1 Hp, (220 ... 240 V AC) Three Phase 1.5 Hp, (440 ... 480 V AC) Three Phase 3 Hp, (550 ... 600 V AC) Three Phase 5 Hp
Full Load Amps Motor Use(200 V AC) Three Phase 6.3 A, (208 V AC) Three Phase 6.3 A, (220 ... 240 V AC) Three Phase 6.3 A, (440 ... 480 V AC) Three Phase 4.8 A, (550 ... 600 V AC) Three Phase 6.1 A
Locked Rotor Amps(200 V AC) Three Phase 37.8 A, (208 V AC) Three Phase 37.8 A, (220 ... 240 V AC) Three Phase 37.8 A, (440 ... 480 V AC) Three Phase 32 A, (550 ... 600 V AC) Three Phase 36.8 A
General Use Rating UL/CSA(600 V AC) 6.3 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-12 AWG, Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSAMain Circuit 10 ... 12 in·lb

Environnement

Température de l’air ambiantAround the Enclosure 0 ... +40 °C, Operation -25 ... +70 °C, Operation Compensated -25 ... +60 °C, Storage -50 ... +80 °C
Ambient Air Temperature CompensationOui
Altitude de fonctionnement maximale autorisée2000 m
Résistance aux chocs selon CEI 60068-2-2711 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-65g / 3 ... 150 Hz
Statut RoHSFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Pourquoi Proax pour ABB MS132-6.3B?

Proax est un distributeur autorisé de ABB MS132-6.3B et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!

Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!

Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Recommandé

Demande de délai de livraison