
By ABB
SKU
MPN
1SBL103004R8101
Weight
1 kg
ASL09 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The ASL..S contactors are the spring terminal version of the ASL... range. The ASL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. ASL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
Spécifications techniques
Dimensions
Produit Largeur Net | 45 mm |
Produit Longueur Net | 72,5 mm |
Produit Hauteur Net | 68 mm |
Poids net | 0,28 kg |
Technique
Number of Main Contacts NO | 3 |
Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 0 |
Number of Auxiliary Contacts NC | 1 |
Normes et standards | IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 |
Tension | Circuit auxiliaire 690 V, Circuit principal 690 V |
Fréquence assignée (f) | Circuit auxiliaire 50 / 60 Hz, Circuit principal 50 / 60 Hz |
Courant thermique conventionnel à l’air libre (Ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 20 A, acc. to IEC 60947-5-1, q = 40 °C 10 A |
Courant assignée d’emploi AC-1 (Ie) | (690 V) 40 °C 20 A, (690 V) 60 °C 15 A, (690 V) 70 °C 12 A |
Courant assignée d’emploi AC-3 (Ie) | (415 V) 60 °C 9 A, (440 V) 60 °C 8 A, (500 V) 60 °C 8 A, (690 V) 60 °C 5 A, (380 / 400 V) 60 °C 9 A, (220 / 230 / 240 V) 60 °C 9 A |
Puissance assignée d’emploi AC-3 (Pe) | (400 V) 4 kW, (415 V) 4 kW, (440 V) 4 kW, (500 V) 4 kW, (690 V) 4 kW, (220 / 230 / 240 V) 2.2 kW |
Courant assignée d’emploi AC-15 (Ie) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (400 / 440 V) 3 A |
Courant assigné de courte durée admissible (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 20 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 230 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 65 A, for 0.1 s 140 A, for 1 s 100 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-2 / AC-4) 300 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
Courant assignée d’emploi DC-13 (Ie) | (24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.27 A / 60 W, (250 V) 0.27 A / 68 W |
Tension assignée d’isolement (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V, acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V, acc. to UL/CSA 600 V |
Tension assignée de tenue aux chocs (Uimp) | Circuit auxiliaire 6 kV |
Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc) | DC Operation 24 V |
Durée de fonctionnement nominale | Entre la mise hors tension de la bobine et la fermeture du contact NC (normally closed) 15 ... 20 ms, Entre la mise hors tension de la bobine et l'ouverture du contact NO (normally open) 13 ... 17 ms, Entre la mise sous tension de la bobine et l'ouverture du contact NC 31 ... 53 ms, Entre la mise sous tension de la bobine et la fermeture du contact NO 36 ... 59 ms |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm², Rigid 1/2x 0.75 ... 2.5 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm², Rigid 1/2x 0.75 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm², Rigid 1/2x 0.75 ... 2.5 mm² |
Wire Stripping Length | Auxiliary Circuit 10 mm, Control Circuit 10 mm, Main Circuit 10 mm |
Indice de protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20, IP20 |
Type de borne | Bornes à ressort |
Technique UL/CSA
General Use Rating UL/CSA | (600 V AC) 12 A |
Puissance nominale UL/CSA | (120 V AC) Single Phase 1/3 hp, (200 ... 208 V AC) Three Phase 2 hp, (220 ... 240 V AC) Three Phase 2 hp, (240 V AC) Single Phase 1 hp, (440 ... 480 V AC) Three Phase 5 hp, (550 ... 600 V AC) Three Phase 7.5 hp |
Environnement
Température de l’air ambiant | Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C |
Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
Altitude de fonctionnement maximale autorisée | Without Derating 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6 | 5 ... 300 Hz 3 g Closed position / 2 g Open position |
Résistance aux chocs selon CEI 60068-2-27 | Closed, Shock Direction: B1 10 g, Closed, Shock Direction: C1 20 g, Closed, Shock Direction: C2 20 g, Open, Shock Direction: B1 5 g, Open, Shock Direction: C1 9 g, Open, Shock Direction: C2 14 g, Shock Direction: A 20 g, Shock Direction: B2 15 g |
Pourquoi Proax pour ABB ASL09-30-01S-81?
Proax est un distributeur autorisé de ABB ASL09-30-01S-81 et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!
Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!
Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Informations complémentaires
Autres noms | ASL093001S81 |
Taille de l'emballage | 1 |
Recommandé
- ASL09 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The ASL..S contactors are the spring terminal version of the ASL... range. The ASL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. ASL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
- ASL09 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The ASL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. ASL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.