Contrôle et protection des moteurs
Relais électronique de puissance à inversion de phases, pour commander directement des appareils triphasés, avec voyant et circuit de protection, sortie : 110-440 V AC/3 x 9 A
Pas en stock
Auxiliary contacts HK1-K with Push-in Spring terminals change position with the main contacts of the manual motor starter. They are mounted laterally on the right side of manual motor starters MS116, MS132 or MS165. Auxiliary contacts HK1-K are available as normally open or normally closed contacts and provide fast connection by tool-free wiring thanks to the innovative Push-in Spring technology.
Pas en stock
The MS132-20L lamp circuit breaker is a compact 45 mm width device with a rated operational current of Ie = 20.0 A. This device is used to manually switch on and off lamp loads (and loads with similar characteristics) and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The lamp circuit breaker offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The lamp circuit breaker is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.
The AF09-30-10-41 is a 3 pole - 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 4 kW / 400 V AC (AC-3) or 5 hp / 480 V UL and switching power circuits up to 25 A (AC-1) or 25 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
CR463 ,Electrically Held,12NO - 0NC Poles , - 120V 60hz , 110V 50hz coil,,Type1,, Lights
Pas en stock
KA165 Terminal Shrouds for MS165/MO165, two pieces for line and load side, increasing degree of protection to IP20
Pas en stock
The AFS09-30-22-13 is a 3 pole - 690 V IEC or 600 V UL contactor with fixed 2 N.O + 2 N.C. front mounted auxiliary contact blocks with screw connections, controlling motors up to 4 kW / 400 V AC (AC-3) or 5 hp / 480 V UL and switching power circuits up to 25 A (AC-1) or 25 A UL general use. AFS contactors can be easily integrated in machine manufacturer’s systems complying with main standards EN ISO 13849 and EN 62061 - guaranteeing the safe use of your machinery and equipment. An easily identifiable yellow low energy auxiliary contact block ensures the status feedback circuits required in machine safety applications. Thanks to the AF technology, the contactor has a wide control voltage range (100 ... 250 V), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Pas en stock
The AFS190-30-12-13 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted 1 left (1 N.O + 1 N.C.) and fixed 1 right (1 N.C.) side mounted auxiliary contact blocks with Main Circuit Bars connections, controlling motors up to 90 kW / 400 V AC (AC-3) or 125 hp / 480 V UL and switching power circuits up to 275 A (AC-1) or 250 A UL general use. AFS contactors can be easily integrated in machine manufacturer’s systems complying with main standards EN ISO 13849 and EN 62061 - guaranteeing the safe use of your machinery and equipment. An easily identifiable yellow low energy auxiliary contact block ensures the status feedback circuits required in machine safety applications. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Pas en stock
MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds.They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.This type has also a clear and reliable indication of fault in a separate window in the event of short-circuittripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanismand a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- andsingle phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts,signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. Theseare suitable throughout the MS132-B/MS165-B range.– designed in accordance to the applicable parts of IEC 60077 standard– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)– usable according to European fire and smoke safety standard EN 45545-2
Pas en stock
The MS132-0.16K manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 0.16 A with Push-in spring terminals. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The MS132-K manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The MS132-K manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory.
Pas en stock
MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds.They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.This type has also a clear and reliable indication of fault in a separate window in the event of short-circuittripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanismand a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- andsingle phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts,signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. Theseare suitable throughout the MS132-B/MS165-B range.– designed in accordance to the applicable parts of IEC 60077 standard– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)– usable according to European fire and smoke safety standard EN 45545-2
Pas en stock
The MS132-0.25K manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 0.25 A with Push-in spring terminals. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The MS132-K manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The MS132-K manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory.
Pas en stock
MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds.They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.This type has also a clear and reliable indication of fault in a separate window in the event of short-circuittripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanismand a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- andsingle phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts,signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. Theseare suitable throughout the MS132-B/MS165-B range.– designed in accordance to the applicable parts of IEC 60077 standard– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)– usable according to European fire and smoke safety standard EN 45545-2
Pas en stock
The circuit breaker for transformer protection MS132-0.4T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 0.4 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks and terminal spacers are available as accessory.
Pas en stock
MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds.They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.This type has also a clear and reliable indication of fault in a separate window in the event of short-circuittripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanismand a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- andsingle phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts,signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. Theseare suitable throughout the MS132-B/MS165-B range.– designed in accordance to the applicable parts of IEC 60077 standard– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)– usable according to European fire and smoke safety standard EN 45545-2
Pas en stock