The CM-TCS.13S relay is from the CM temperature monitors range. This relay operates with a rated control supply voltage of 24 - 240 V AC / DC and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A. The CM-TCS.13S is able to measure temperature with 1 sensor circuit using PT100 sensor. The CM-TCS.13S monitors overtemperature, undertemperature and window monitoring with 2 thresholds. The corresponding threshold values are adjustable. The temperature measuring range is 0..+200°C. A sealable transparent cover for protection against unauthorized changes is available as accessory. The device offers screw connection technology with double-chamber cage connection terminals.
Pas en stock
The CM-TCS.22S relay is from the CM temperature monitors range. This relay operates with a rated control supply voltage of 24 V AC / DC and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A. The CM-TCS.22S is able to measure temperature with 1 sensor circuit using PT100 sensor. The CM-TCS.22S monitors overtemperature, undertemperature and window monitoring with 2 thresholds. The corresponding threshold values are adjustable. The temperature measuring range is 0..+100°C. A sealable transparent cover for protection against unauthorized changes is available as accessory. The device offers screw connection technology with double-chamber cage connection terminals.
Pas en stock
Huit amplificateurs-séparateurs et convertisseurs de mesure MINI Analog Pro s'intègrent facilement et rapidement dans un réseau Modbus/TCP à l'aide d'un adaptateur de communication.
Pas en stock
The CM-IWS.1P serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems, IT AC systems with galvanically connected DC circuits, or unearthed IT DC systems with a voltage up to 250 V AC and 300 V DC. It can be configured to therequirements of the applications and therefore used multi-functional.
Pas en stock
Huit amplificateurs-séparateurs et convertisseurs de mesure MINI Analog Pro s'intègrent facilement et rapidement dans un réseau PROFIBUS DP à l'aide d'un adaptateur de communication.
Pas en stock
The CM-IWS.2P serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems with a voltage up to 400 V AC. The CM-IWS.2 can be configured to the requirements of the applications and therefore used multi-functional.
Pas en stock
The CM-TCS.12P relay is from the CM temperature monitors range. This relay operates with a rated control supply voltage of 24 - 240 V AC / DC and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A. The CM-TCS.12P is able to measure temperature with 1 sensor circuit using PT100 sensor. The CM-TCS.12P monitors overtemperature, undertemperature and window monitoring with 2 thresholds. The corresponding threshold values are adjustable. The temperature measuring range is 0..+100°C. A sealable transparent cover for protection against unauthorized changes is available as accessory. The device offers maintenance free Easy Connect Technology with push-in terminals.
Pas en stock
Bloc de commande de vanne Ex i pour commande d'électrovannes Ex i en zone Ex, entrée logique, tension de marche à vite de 21,1 V, limitation de courant à 25,1 mA, transparence des défauts de câblage et avec sortie de signalisation de défaut jusqu'à SIL 3 selon CEI 61508 ; raccordement vissé.
Pas en stock
The CM-TCS.13P relay is from the CM temperature monitors range. This relay operates with a rated control supply voltage of 24 - 240 V AC / DC and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A. The CM-TCS.13P is able to measure temperature with 1 sensor circuit using PT100 sensor. The CM-TCS.13P monitors overtemperature, undertemperature and window monitoring with 2 thresholds. The corresponding threshold values are adjustable. The temperature measuring range is 0..+200°C. A sealable transparent cover for protection against unauthorized changes is available as accessory. The device offers maintenance free Easy Connect Technology with push-in terminals.
Pas en stock
Bloc de commande de vanne Ex i pour commande d'électrovannes Ex i en zone Ex, entrée logique, tension de marche à vite de 21,1 V, limitation de courant à 25,1 mA, transparence des défauts de câblage et avec sortie de signalisation de défaut jusqu'à SIL 3 selon CEI 61508 ; raccordement Push-in.
Pas en stock
The CM-PFS.P relay is from the CM three-phase monitors range. This relay operates with a rated control supply voltage / three-phase measuring voltage of 200-500 V AC and has a 2 c/o output with contacts rated at 250 V / 4 A. The CM-PFS.P monitors the phase loss and phase sequence. The corresponding threshold values are fixed. The device offers maintenance free Easy Connect Technology with push-in terminals.
Pas en stock
Termination Carrier pour la connexion redondante de 16 amplificateurs-séparateurs MACX Analog Ex i aux cartes d'entrée analogiques de la commande Yokogawa CENTUM VP, via deux connecteurs KS40 à 40 pôles. Adapté pour les cartes Yokogawa AAI141 et AAI143.
Pas en stock
The CM-IWN.1S serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems, IT AC systems with galvanically connected DC circuits, or unearthed IT DC systems with a voltage up to 400 V AC and 600 V DC. The measuring range can be extended up to 690 V AC and 1000 V DC by using the coupling unit CM-IVN. It can be configured to the requirements of the applications and therefore used multi-functional.
Pas en stock
Termination Carrier pour la connexion redondante de 16 blocs de commande de vanne MACX Analog Ex-i aux cartes d'entrée/sortie TOR de la commande Yokogawa ProSafe-RS, via deux connecteurs KS50 à 50 pôles. Compatible avec la carte Yokogawa SDV541.
Pas en stock
The CM-IWN.1P serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems, IT AC systems with galvanically connected DC circuits, or unearthed IT DC systems with a voltage up to 400 V AC and 600 V DC. The measuring range can be extended up to 690 V AC and 1000 V DC by using the coupling unit CM-IVN. It can be configured to the requirements of the applications and therefore used multi-functional.
Pas en stock
Borne de raccordement pour signaux électriques, +20 mA ...-20 mA, pour la commutation sécurisée de valeurs seuil, à combiner avec le convertisseur de température MACX ...EX-T-UI...
Pas en stock
Module d'espace réservé non fonctionnel pour la pose des câbles de signalisation à sécurité intrinsèque non utilisés, avec blocs de jonction Push-in.
Pas en stock
Transformateur de courant enfichable, courant primaire 200 A AC ; courant secondaire 1 A AC ; classe de précision 1 ; puissance assignée 5 VA
Pas en stock
Transformateur de courant enfichable, courant primaire 250 A AC ; courant secondaire 1 A AC ; classe de précision 1 ; puissance assignée 5 VA
Pas en stock