The circuit breaker for transformer protection MS132-16T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 16 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks and terminal spacers are available as accessory.
Spécifications techniques
Dimensions
Produit Largeur Net | 45 mm |
Produit Hauteur Net | 97,8 mm |
Produit Longueur Net | 86.05 mm |
Poids net | 0,31 kg |
Technique
Pourvoir assigné de coupure de service en court-circuit (Ics) | (230 V AC) 100 kA, (400 V AC) 100 kA, (440 V AC) 30 kA |
Pouvoir assigné de coupure ultime en court-circuit (Icu) | (400 V AC) 100 kA |
Courant assigné instantané de réglage de court-circuit (Ii) | 320 A |
Setting Range | 10 ... 16 A |
Tension | Circuit principal 690 V AC |
Courant nominal de fonctionnement (Ie) | 16 A |
Fréquence assignée (f) | Circuit principal 50 Hz, Circuit principal 60 Hz |
Tension assignée de tenue aux chocs (Uimp) | Circuit principal 6 kV |
Tension assignée d’isolement (Ui) | 690 V |
Power Loss | at Rated Operating Conditions per Pole 0.9 ... 2.3 W |
Nombre de pôles | 3 |
Courant thermique conventionnel à l’air libre (Ith) | Main Circuit 16 A |
Indice de protection | Housing IP20, Main Circuit Terminals IP10 |
Degré de pollution | 3 |
Electrical Durability | 50000 cycle |
Durabilite mecanique | 100000 cycle |
Type de borne | Bornes à vis |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 6 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm², Flexible 1/2x 1 ... 2.5 mm², Flexible 1/2x 2.5 ... 6 mm², Rigid 1/2x 1 ... 2.5 mm², Rigid 1/2x 2.5 ... 6 mm² |
Couple de serrage | Main Circuit 2 N·m |
Wire Stripping Length | Main Circuit 10 mm |
Recommended Screw Driver | M4, Pozidriv 2 |
Type d'encastrement | 1 ... 6 |
Montage sur rail DIN | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Minimum Mounting Distance | Electrical Conductive Board, Vertical 75 mm, Other Device Same Type, Horizontal 9 mm, Other Device Same Type, Vertical 150 mm |
Actuator Type | POIGNÉE ROTATIVE |
Contact Position Indication | ON / OFF / TRIP |
Normes et standards | IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1 |
Technique UL/CSA
Short-Circuit Current Rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA, Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA |
Maximum Operating Voltage UL/CSA | Circuit principal 600 V AC |
Puissance nominale UL/CSA | (120 V AC) Single Phase 1 Hp, (220 ... 240 V AC) Single Phase 2 Hp |
Full Load Amps Motor Use | (120 V AC) Single Phase 16 A, (220 ... 240 V AC) Single Phase 12 A |
Locked Rotor Amps | (120 V AC) Single Phase 96 A, (220 ... 240 V AC) Single Phase 96 A |
Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-8 AWG, Stranded 1/2x 16-8 AWG |
Tightening Torque UL/CSA | Main Circuit 16 in·lb |
Environnement
Température de l’air ambiant | Around the Enclosure 0 ... +40 °C, Operation -25 ... +70 °C, Operation Compensated -25 ... +60 °C, Storage -50 ... +80 °C |
Ambient Air Temperature Compensation | Oui |
Altitude de fonctionnement maximale autorisée | 2000 m |
Résistance aux chocs selon CEI 60068-2-27 | 11 ms Pulse 25g |
Resistance to Vibrations acc. to IEC 60068-2-6 | 5g / 3 ... 150 Hz |
Statut RoHS | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Pourquoi Proax pour ABB MS132-16T?
Proax est un distributeur autorisé de ABB MS132-16T et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!
Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!
Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Informations complémentaires
Autres noms | MS13216T |
Taille de l'emballage | 1 |
Recommandé
- The MS132-16L lamp circuit breaker is a compact 45 mm width device with a rated operational current of Ie = 16.0 A. This device is used to manually switch on and off lamp loads (and loads with similar characteristics) and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The lamp circuit breaker offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The lamp circuit breaker is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.
- The MS132-16K manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 16.0 A with Push-in spring terminals. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The MS132-K manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The MS132-K manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory.
- MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds.They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.This type has also a clear and reliable indication of fault in a separate window in the event of short-circuittripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanismand a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- andsingle phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts,signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. Theseare suitable throughout the MS132-B/MS165-B range.– designed in accordance to the applicable parts of IEC 60077 standard– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)– usable according to European fire and smoke safety standard EN 45545-2
- The circuit breaker for transformer protection MS132-12T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 12 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks and terminal spacers are available as accessory.
- The MS132-16 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 16.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.
- The circuit breaker for transformer protection MS132-10T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 10 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks and terminal spacers are available as accessory.
- The circuit breaker for transformer protection MS132-25T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 25 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 50 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks and terminal spacers are available as accessory.
- MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds.They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.This type has also a clear and reliable indication of fault in a separate window in the event of short-circuittripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanismand a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- andsingle phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts,signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. Theseare suitable throughout the MS132-B/MS165-B range.– designed in accordance to the applicable parts of IEC 60077 standard– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)– usable according to European fire and smoke safety standard EN 45545-2
- The MS132-25L lamp circuit breaker is a compact 45 mm width device with a rated operational current of Ie = 25.0 A. This device is used to manually switch on and off lamp loads (and loads with similar characteristics) and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The lamp circuit breaker offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The lamp circuit breaker is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.
- The MS132-25K manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 25.0 A with Push-in spring terminals. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The MS132-K manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The MS132-K manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory.
- The MS132-12 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 12.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.
- MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds.They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.This type has also a clear and reliable indication of fault in a separate window in the event of short-circuittripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanismand a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- andsingle phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts,signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. Theseare suitable throughout the MS132-B/MS165-B range.– designed in accordance to the applicable parts of IEC 60077 standard– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)– usable according to European fire and smoke safety standard EN 45545-2
- The MS132-10 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 10.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.
- The MS132-25 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 25.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.
- The circuit breaker for transformer protection MS132-20T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 20 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks and terminal spacers are available as accessory.
- The MS132-20L lamp circuit breaker is a compact 45 mm width device with a rated operational current of Ie = 20.0 A. This device is used to manually switch on and off lamp loads (and loads with similar characteristics) and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The lamp circuit breaker offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The lamp circuit breaker is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.