The MS132-16L lamp circuit breaker is a compact 45 mm width device with a rated operational current of Ie = 16.0 A. This device is used to manually switch on and off lamp loads (and loads with similar characteristics) and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The lamp circuit breaker offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The lamp circuit breaker is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.
Spécifications techniques

Dimensions

Produit Largeur Net3 mm
Produit Hauteur Net2 mm
Produit Longueur Net1 mm
Poids net0,31 kg

Technique

Pourvoir assigné de coupure de service en court-circuit (Ics)(230 V AC) 100 kA, (250 V DC) 3 Poles in Series 10 kA, (400 V AC) 100 kA, (440 V AC) 30 kA, (500 V AC) 20 kA, (690 V AC) 3 kA
Pouvoir assigné de coupure ultime en court-circuit (Icu)(230 V AC) 100 kA, (400 V AC) 100 kA, (440 V AC) 30 kA, (500 V AC) 20 kA, (690 V AC) 3 kA
Courant assigné instantané de réglage de court-circuit (Ii)240 A
Setting Range10 ... 16 A
Puissance assignée d’emploi AC-3 (Pe)(400 V) Three Phase 7.5 kW
TensionCircuit principal 690 V AC, Circuit principal 250 V DC
Courant nominal de fonctionnement (Ie)16 A
Courant assignée d’emploi AC-3 (Ie)16 A
Courant assignée d’emploi DC-5 (Ie)16 A
Fréquence assignée (f)Circuit principal 50 Hz, Circuit principal 60 Hz
Tension assignée de tenue aux chocs (Uimp)Circuit principal 6 kV
Tension assignée d’isolement (Ui)690 V
Nombre de pôles3
Courant thermique conventionnel à l’air libre (Ith)Main Circuit 16 A
Indice de protectionHousing IP20, Main Circuit Terminals IP10
Degré de pollution3
Electrical Durability50000 cycle
Durabilite mecanique100000 cycle
Type de borneBornes à vis
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm², Flexible 1/2x 1 ... 2.5 mm², Flexible 1/2x 2.5 ... 6 mm², Rigid 1/2x 1 ... 2.5 mm², Rigid 1/2x 2.5 ... 6 mm²
Couple de serrageMain Circuit 2 N·m
Wire Stripping LengthMain Circuit 10 mm
Recommended Screw DriverPozidriv 2
Type d'encastrementany; 1 ... 6
Montage sur rail DINTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 400 V 0 mm, Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm, Electrical Conductive Board, Vertical 75 mm, Other Device Same Type, Horizontal 0 mm, Other Device Same Type, Vertical 150 mm
Actuator TypePOIGNÉE ROTATIVE
Contact Position IndicationON / OFF / TRIP
Normes et standardsIEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1

Technique UL/CSA

Short-Circuit Current Rating (SCCR)Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kA, Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA, Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA, Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA, Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA, Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA, Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Maximum Operating Voltage UL/CSACircuit principal 600 V AC
Puissance nominale UL/CSA(200 V AC) Three Phase 3 Hp, (208 V AC) Three Phase 3 Hp, (220 ... 240 V AC) Three Phase 5 Hp, (440 ... 480 V AC) Three Phase 10 Hp, (550 ... 600 V AC) Three Phase 10 Hp
Full Load Amps Motor Use(200 V AC) Three Phase 11 A, (208 V AC) Three Phase 10.6 A, (220 ... 240 V AC) Three Phase 15.2 A, (440 ... 480 V AC) Three Phase 14 A, (550 ... 600 V AC) Three Phase 11 A
Locked Rotor Amps(200 V AC) Three Phase 73.6 A, (208 V AC) Three Phase 71 A, (220 ... 240 V AC) Three Phase 92 A, (440 ... 480 V AC) Three Phase 81 A, (550 ... 600 V AC) Three Phase 64.8 A
General Use Rating UL/CSA(600 V AC) 16 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-8 AWG, Stranded 1/2x 16-8 AWG
Tightening Torque UL/CSAMain Circuit 18 in·lb

Environnement

Température de l’air ambiantAround the Enclosure 0 ... +40 °C, Operation -25 ... +70 °C, Operation Compensated -25 ... +60 °C, Storage -50 ... +80 °C
Ambient Air Temperature CompensationOui
Altitude de fonctionnement maximale autorisée2000 m
Résistance aux chocs selon CEI 60068-2-2711 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-65g / 3 ... 150 Hz
Statut RoHSFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Pourquoi Proax pour ABB MS132-16L?

Proax est un distributeur autorisé de ABB MS132-16L et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!

Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!

Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Informations complémentaires

Autres nomsMS13216L
Taille de l'emballage1
Recommandé

Disponible à l'achat

ABB Disponibilité