By ABB

ABBCA411ERT
Weight 0 kg
ABBDistributeur Officiel
The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for standard industrial environments.Types of auxiliary contact blocks for front mounting:• CA4 1 or 4-pole block, with instantaneous N.O., N.C. contacts• CC4 1-pole block, with N.O. leading contact or N.C. lagging contact• CAT4 2-pole block, with instantaneous N.O. + N.C. contacts and A1 / A2 coil terminal connection on front face.Select the 4-pole auxiliary contact blocks CA4-..E, CA4-..M, CA4-..U or CA4-..N type, according to the contactor or contactor relay type for compliance with the standard requirements (see "Terminal marking and positioning").Types of auxiliary contact blocks for side mounting:• CAL4 2-pole block, with instantaneous N.O. + N.C. contacts.For clipping onto the right- and/or left-hand side of the contactors. The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function marking.
Spécifications techniques

Dimensions

Produit Largeur Net45 mm
Produit Longueur Net39,8 mm
Produit Hauteur Net43 mm
Poids net0,04 kg

Technique

Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour, (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Type de montageMontage frontal
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Fréquence assignée (f)Circuit auxiliaire 50 / 60 Hz
Tension assignée de tenue aux chocs (Uimp)6 kV
Tension assignée d’isolement (Ui)acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V, acc. to UL/CSA 600 V
Courant assignée d’emploi AC-15 (Ie)(500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (400 / 440 V) 3 A
Courant assignée d’emploi DC-13 (Ie)(24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.27 A / 60 W, (250 V) 0.27 A / 68 W, (400 V) 0.15 A / 60 W, (500 V) 0.13 A / 65 W, (600 V) 0.1 A / 60 W
TensionCircuit auxiliaire 690 V
Courant assigné de courte durée admissible (Icw)for 0.1 s 140 A, for 1 s 100 A
Normes et standardsIEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14
Adapté pourAF09B, AF09ZB, AF12B, AF12ZB, AF16B, AF16ZB, AF26B, AF26ZB, AF30B, AF30ZB, AF38B, AF38ZB
Type de borneRing-Tongue Terminals
Couple de serrageAuxiliary Circuit 1.2 N·m

Technique UL/CSA

Pilot Duty UL/CSAA600, Q600

Environnement

Courant thermique conventionnel à l’air libre (Ith)acc. to IEC 60947-5-1, q = 40 °C 16 A
Indice de protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Informations RoHS2CMT2021-006277
DEEE B2C / B2BBusiness To Business

Pourquoi Proax pour ABB CA4-11ERT?

Proax est un distributeur autorisé de ABB CA4-11ERT et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!

Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!

Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Recommandé

Demande de délai de livraison