AF1650-30-11-70

ABBDistributeur Officiel

By ABB

SKU
ABBAF1650301170
MPN
1SFL677001R7011
Weight
33 kg
Cet article n’est pas admissible à la livraison gratuite en raison de sa taille.
The AF1650-30-11-70 is a 3 pole - 1000 V IEC or 1000 V UL contactor pre-mounted auxiliary contacts and and Main Circuit Bars, controlling motors up to 560 kW / 400 V AC (AC-3) or 900 hp / 480 V UL and switching power circuits up to 1650 A (AC-1) or 1650 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Spécifications techniques

Dimensions

Produit Largeur Net438 mm
Produit Longueur Net244 mm
Produit Hauteur Net392 mm
Poids net33 kg

Technique

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
TensionCircuit principal 1000 V
Fréquence assignée (f)Circuit principal 50 / 60 Hz
Courant thermique conventionnel à l’air libre (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 1650 A
Courant assignée d’emploi AC-1 (Ie)(1000 V) 40 °C 1650 A, (1000 V) 55 °C 1450 A, (1000 V) 70 °C 1270 A, (690 V) 40 °C 1650 A, (690 V) 55 °C 1450 A, (690 V) 70 °C 1270 A
Courant assignée d’emploi AC-3 (Ie)(415 V) 55 °C 1060 A, (440 V) 55 °C 1060 A, (500 V) 55 °C 970 A, (690 V) 55 °C 970 A, (1000 V) 55 °C 400 A, (380 / 400 V) 55 °C 1060 A, (220 / 230 / 240 V) 55 °C 1060
Puissance assignée d’emploi AC-3 (Pe)(415 V) 630 kW, (440 V) 710 kW, (500 V) 710 kW, (690 V) 1000 kW, (1000 V) 600 kW, (380 / 400 V) 560 kW, (220 / 230 / 240 V) 315 kW
Pouvoir assigné de fermeture AC-310 x Ie AC-3
Courant assigné de courte durée admissible (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 10000 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 2200 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 5500 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 12000 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 7500 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 12000 A
Maximum Electrical Switching Frequency(AC-1) 60 cycles per hour, (AC-2 / AC-4) 60 cycles per hour, (AC-3) 60 cycles per hour
Courant assignée d’emploi DC-1 (Ie)(110 V) 1-Pole, 40 °C 1650 A, (110 V) 2 Poles in Series, 40 °C 1650 A, (220 V) 3 Poles in Series, 40 °C 1650 A, (600 V) 3 Poles in Series, 40 °C 1650 A, (850 V) 3 Poles in Series, 40 °C 1650 A
Tension assignée d’isolement (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 1000 V
Tension assignée de tenue aux chocs (Uimp)Circuit principal 8 kV
Durabilite mecanique0.5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Plage d'utilisation de la bobine selon(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V, 60 Hz 100 ... 250 V, DC Operation 100 ... 250 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 48 V·A, Holding at Max. Rated Control Circuit Voltage 60 Hz 48 V·A, Holding at Max. Rated Control Circuit Voltage DC 20.5 V·A, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 2450 V·A, Pull-in at Max. Rated Control Circuit Voltage 60 Hz 2450 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 2290 V·A
Durée de fonctionnement nominaleEntre la mise hors tension de la bobine et la fermeture du contact NC (normally closed) 35 ... 55 ms, Entre la mise hors tension de la bobine et l'ouverture du contact NO (normally open) 35 ... 55 ms, Entre la mise sous tension de la bobine et l'ouverture du contact NC 50 ... 80 ms, Entre la mise sous tension de la bobine et la fermeture du contact NO 50 ... 80 ms
Connecting Capacity Main CircuitBar 100 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible 2x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 2 x 1 .... 4 mm²
Indice de protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Type de borneMain Circuit: Bars

Technique UL/CSA

NEMA Size8
Horsepower Rating NEMA(230 V AC) Three Phase 450 Hp, (460 V AC) Three Phase 900 Hp, (575 V AC) Three Phase 900 Hp
Maximum Operating Voltage UL/CSACircuit principal 1000 V
General Use Rating UL/CSA(1000 V AC) 1650 A, (600 V AC) 1650 A
Puissance nominale UL/CSA(220 ... 240 V AC) Three Phase 450 hp, (440 ... 480 V AC) Three Phase 900 hp, (550 ... 600 V AC) Three Phase 1150 hp

Environnement

Température de l’air ambiantClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C, Close to Contactor for Storage -40 ... +70 °C
Altitude de fonctionnement maximale autoriséeWithout Derating 3000 m
Statut RoHSFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Pourquoi Proax pour ABB AF1650-30-11-70?

Proax est un distributeur autorisé de ABB AF1650-30-11-70 et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!

Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!

Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Informations complémentaires
Autres nomsAF1650301170
Taille de l'emballage1