For switch-disconnectors with wide phase distance (140 mm or 185 mm). Supporting 12 mm shafts longer than 280 mm for OT1000...2500.
Pas en stock
The ZLS100 is a busbar cover electrically protected covering of main and auxiliary busbars. The 4 modules cover can be divided. Suitable to accept extension adapter ZLS 101 4x18 mm – bag containing 5 items
Pas en stock
Incoming terminal Feeder component N with 2 Modules 36mm width, 200A; 10 mm2 up to 95 mm2 max. 1 wire. For the SMISSLINE TP 125A and 250A system
Pas en stock
The EPD24 protection devices expand ABB's product portfolio of DIN rail mounted devices with electronic overcurrent protection modules for selective protection of 24 V DC load circuits. Faults in individual branches caused by overload or short circuit are detected and selectively switched off so that other load current paths remain unaffected by the fault. In this way straightforward, quick troubleshooting is made possible.
Pas en stock
The EPD24 protection devices expand ABB's product portfolio of DIN rail mounted devices with electronic overcurrent protection modules for selective protection of 24 V DC load circuits. Faults in individual branches caused by overload or short circuit are detected and selectively switched off so that other load current paths remain unaffected by the fault. In this way straightforward, quick troubleshooting is made possible.
Pas en stock
The EPD24 protection devices expand ABB's product portfolio of DIN rail mounted devices with electronic overcurrent protection modules for selective protection of 24 V DC load circuits. Faults in individual branches caused by overload or short circuit are detected and selectively switched off so that other load current paths remain unaffected by the fault. In this way straightforward, quick troubleshooting is made possible.
Pas en stock
OMD automatic control units can be used with OTM40…2500_CM_ motorized change-over switches in order to assemble an automatic transfer switch. The type and ordering codes include the OMD control unit, PCB connectors and 2 fasteners for door mounting.
Pas en stock
Switch Fuses,Front Operated,3-pole,03 (Left Side),British Standard,A2-A4,Handle and shaft not included,
Pas en stock
Switch Fuses,Front Operated,3-pole,12 (Between the Poles),NFC,22x58,Handle and shaft not included,
Pas en stock
Switch Fuses,Front operated,4-pole,04 (Left Side),Class J,200 A,Handle and shaft not included,Switched - Fusible Pole
Pas en stock
Switch Fuses,Front Operated,4-pole,22 (Between the Poles),Class J,200 A,Handle and shaft not included,Switched - Fusible Pole