Contacteurs
Parallel and series connection of 3-pole contactors:• To obtain a star point (3 parallel-connected poles)• To connect poles in parallel and thus increase the AC load passing through the flow path made up of the parallel-connected poles: LP, LY, LH, LF, LG.The relevant cable cross-sectional area may limit the maximum permissible current. Consult information in table below• To connect poles in series and thus increase the DC voltage controlled by the poles: LP, LY (only LY16-4 and LY38-4 secable strips).
Pas en stock
2 pole parallel or series connection busbar, parallel connected poles to increase the a.c. load or series connection for d.c. loads
Pas en stock
2 pole parallel or series connection busbar, parallel connected poles to increase the a.c. load or series connection for d.c. loads
Pas en stock
2 pole parallel or series connection busbar, parallel connected poles to increase the a.c. load or series connection for d.c. loads
Pas en stock
Protection for main terminals achieving finger protection from life parts. For Contactors A145…A185 in combination with connectors
Pas en stock
Protection formain terminals achieving finger protection from life parts. For Contactors A145…A185 incombination with lugs
Pas en stock
Protection for main terminals achieving finger protection from life parts. For Contactors A145…A185 and between Overload relay TA 200DU
Pas en stock
Protection for main terminals achieving finger protection from life parts. For Contactors A210…A300 incombination with lugs
Pas en stock
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Magnetically latch, control voltage 110-125 V, AC/DC latch
Pas en stock
Protection for main terminals achieving finger protection from life parts. For Contactors A210…A300 incombination shorting bar LY300
Pas en stock
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Magnetically latch, control voltage 220-240 V, AC/DC latch
Pas en stock
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Magnetically latch, control voltage 110-125 V, AC/DC latch
Pas en stock
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Magnetically latch, control voltage 220-240 V, AC/DC latch
Pas en stock
The LT6-B Mini Contactor Cover Cap is a sealable and transparent protective covers to protect the devices against accidental contact. The LT6-B Cover Cap is sealable and can be easily clipped onto all B6, BC6, B7, BC7, K6 and KC6 mini contactors.
Pas en stock