CADFR
Cart

Démarreur progressif

1,105 articles
PSEHMI-1
HMI MODULE PSE#PSEHMI-1
Pas en stock
PSHMI-1
HMI MODULE PST
Pas en stock
PSHMI-2
HMI MODULE PSTB
Pas en stock
PSPB-1
PSTX30...PSTX370 Kit for replacing SCR, for 10 thyristor blocks
Pas en stock
PSPCB-690/T-T
PRINTED CIRCUIT BOARD#PSPCB-690/T-T
Pas en stock
PSPCB-LV/T-T
PRINTED CIRCUIT BOARD#PSPCB-LV/T-T
Pas en stock
PSR12-600-11
The softstarter PSR12-600-11 has a rated maximum operational current of 12 A with an operating voltage span from 208...600 V AC. The rated control voltage is 24 V AC/DC. PSR features a two-phase control soft start and stop through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN signal is available from a relay output in NO (normally open state). The start/stop ramp and time is easy to set by three potentiometers on the front. PSR is often used in combination with a manual motor starter (MMS) from ABB, so mechanical connection kits are available. Another popular option is Fieldbus communication, which can be enabled by an external adaptor and a Fieldbus plug. The PSR range is our most compact softstarters with basic functionality and values. They are suitable for small three-phase motors with nominal currents from 3...105 A and can manage up to 100 starts per hour. Common applications are, for example, pumps, fans, compressors, and conveyors.
Pas en stock
PSR12-600-70
The softstarter PSR12-600-70 has a rated maximum operational current of 12 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSR features a two-phase control soft start and stop through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN signal is available from a relay output in NO (normally open state). The start/stop ramp and time is easy to set by three potentiometers on the front. PSR is often used in combination with a manual motor starter (MMS) from ABB, so mechanical connection kits are available. Another popular option is Fieldbus communication, which can be enabled by an external adaptor and a Fieldbus plug. The PSR range is our most compact softstarters with basic functionality and values. They are suitable for small three-phase motors with nominal currents from 3...105 A and can manage up to 100 starts per hour. Common applications are, for example, pumps, fans, compressors, and conveyors.
Pas en stock
PSR16-MS116
Connection kit for PSR3…PSR16 with MS116 or MS132
Pas en stock
PSR3-600-70
The softstarter PSR3-600-70 has a rated maximum operational current of 3 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSR features a two-phase control soft start and stop through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN signal is available from a relay output in NO (normally open state). The start/stop ramp and time is easy to set by three potentiometers on the front. PSR is often used in combination with a manual motor starter (MMS) from ABB, so mechanical connection kits are available. Another popular option is Fieldbus communication, which can be enabled by an external adaptor and a Fieldbus plug. The PSR range is our most compact softstarters with basic functionality and values. They are suitable for small three-phase motors with nominal currents from 3...105 A and can manage up to 100 starts per hour. Common applications are, for example, pumps, fans, compressors, and conveyors.
Pas en stock
PSR72-600-70
The softstarter PSR72-600-70 has a rated maximum operational current of 72 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSR features a two-phase control soft start and stop through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN and a TOR signal is available from a relay output in NO (normally open state). The start/stop ramp and time is easy to set by three potentiometers on the front. PSR is often used in combination with a manual motor starter (MMS) from ABB, so mechanical connection kits are available. Another popular option is Fieldbus communication, which can be enabled by an external adaptor and a Fieldbus plug. The PSR range is our most compact softstarters with basic functionality and values. They are suitable for small three-phase motors with nominal currents from 3...105 A and can manage up to 100 starts per hour. Common applications are, for example, pumps, fans, compressors, and conveyors.
Pas en stock
PSTHM-132/16
THYRISTOR#PSTHM-132/16
Pas en stock
PSTHM-162/16
THYRISTOR#PSTHM-162/16
Pas en stock
PSTHM-200/16
THYRISTOR#PSTHM-200/16
Pas en stock
PSTHM-26/16
THYRISTOR#PSTHM-26/16
Pas en stock
PSTHM-312/16
THYRISTOR#PSTHM-312/16
Pas en stock
PSTHM-44/16
THYRISTOR#PSTHM-44/16
Pas en stock
PSTHM-501/16
THYRISTOR#PSTHM-501/16
Pas en stock
PSTHM-56/16
THYRISTOR#PSTHM-56/16
Pas en stock
PSTHM-95/16
THYRISTOR#PSTHM-95/16
Pas en stock

1105 Articles