CADFR
Cart

ABB Moteurs et Variateurs de fréquences

3,120 articles
ACS580-01-017A-6
VBD 580 15HP NDT/10HDT 600V FRAME R2
1 En stock
Windsor, ON
1
ACS580-01-011A-6
Drive, AC, 7.5HP, 575V, 9.0A, CT, N1 575Vin 3PH 10HP 11.0A VT W/DB Trans 18.6"Hx4.9"Wx9.0"D
4 En stock
Laval, QC
4
ACS580-01-041A-6
ACS580 600V 40HPld/30HPhd; Nema 1
Pas en stock
ACS5800102A76
ACS580 Drive, 2.0HP, 575V/3PH 2.7A
5 En stock
Laval, QC
5
ACS580-01-032A-6
Drive, AC, 25HP, 575V, 27.0A, CT, N1 575Vin 3PH 30HP 32.0A VT W/DB Trans 19.3"Hx8.0"Wx9.0"D
2 En stock
Laval, QC
2
ACS-CP-A
ACS-CP-A, ASSISTANT CONTROL PANEL
Pas en stock
ACS580-01-022A-6
ACS580-01-022A-6
1 En stock
Windsor, ON
1
ACS580-01-077A-6
ACS580 DRIVE 75HP 600V
Pas en stock
ACS580-01-027A-6
ACS580 600V 27Amp
2 En stock
Laval, QC
2
ACS880-01-180A-5
ACS880 480V 150HPld/125HPhd
2 En stock
Mississauga, ON
1
Vancouver, BC
1
ACS880-01-035A-7
ACS880 600V 40HPld/30HPhd
Pas en stock
ACS580-01-09A0-6
Drive ACS580
2 En stock
Laval, QC
2
ACS580-01-06A1-6
ACS580-01-06A1-6
4 En stock
Laval, QC
4
ACS255-03U-02A1-6
LV AC micro drive, 600 V (ACS255-03U-02A1-6)
1 En stock
Laval, QC
1
ACS25503U06A56
DRIVE 5HP 600V
Pas en stock
PSTX60-690-70
The softstarter PSTX60-690-70 has a rated maximum operational current of 60 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard.To interact with PSTX, it has a detachable full graphic display with IP66 and 4x outdoor rating. There are four ways to communicate with PSTX. It can be done by hardwire inputs Start/Stop/Reset of fault, and by three programmable digital inputs. Another popular option is the built-in Fieldbus communication Modbus RTU and incl optional ANYBUS modules with every major protocol such as for example Profinet, Profibus, Modbus TCP, Ethernet IP and others. Another way to communicate with PSTX is to use an external adaptor and a Fieldbus plug. PSTX is the complete alternative for any motor starting application. It’s suitable for medium to large-sized three-phase motors with nominal currents from 30...1250 A inline connection or 52...2160 A inside delta connection. Typical applications are, for example, pumps, fans, compressors, and conveyors.
Pas en stock
PSTX72-690-70
The softstarter PSTX72-690-70 has a rated maximum operational current of 72 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard.To interact with PSTX, it has a detachable full graphic display with IP66 and 4x outdoor rating. There are four ways to communicate with PSTX. It can be done by hardwire inputs Start/Stop/Reset of fault, and by three programmable digital inputs. Another popular option is the built-in Fieldbus communication Modbus RTU and incl optional ANYBUS modules with every major protocol such as for example Profinet, Profibus, Modbus TCP, Ethernet IP and others. Another way to communicate with PSTX is to use an external adaptor and a Fieldbus plug. PSTX is the complete alternative for any motor starting application. It’s suitable for medium to large-sized three-phase motors with nominal currents from 30...1250 A inline connection or 52...2160 A inside delta connection. Typical applications are, for example, pumps, fans, compressors, and conveyors.
Pas en stock
ACS25503U03A16
DRIVE 2HP 600V
Pas en stock
ACS580-01-052A-4
LV AC general purpose wall-mounted drive, UL: Pld 40 Hp, 52 A, 500 V (ACS580-01-052A-4)
Pas en stock
ACQ580-01-062A-6
ACQ-580 600V 60HPld/50HPhd; IP21 R5 FRAME
1 En stock
Laval, QC
1

3120 Articles