CADFR
Cart
1,869 Products
Filtres

Mesure et surveillance

1,869 articles
CM-TCS.13P
The CM-TCS.13P relay is from the CM temperature monitors range. This relay operates with a rated control supply voltage of 24 - 240 V AC / DC and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A. The CM-TCS.13P is able to measure temperature with 1 sensor circuit using PT100 sensor. The CM-TCS.13P monitors overtemperature, undertemperature and window monitoring with 2 thresholds. The corresponding threshold values are adjustable. The temperature measuring range is 0..+200°C. A sealable transparent cover for protection against unauthorized changes is available as accessory. The device offers maintenance free Easy Connect Technology with push-in terminals.
Pas en stock
CM-PFS.P
The CM-PFS.P relay is from the CM three-phase monitors range. This relay operates with a rated control supply voltage / three-phase measuring voltage of 200-500 V AC and has a 2 c/o output with contacts rated at 250 V / 4 A. The CM-PFS.P monitors the phase loss and phase sequence. The corresponding threshold values are fixed. The device offers maintenance free Easy Connect Technology with push-in terminals.
Pas en stock
CM-IWN.1S
The CM-IWN.1S serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems, IT AC systems with galvanically connected DC circuits, or unearthed IT DC systems with a voltage up to 400 V AC and 600 V DC. The measuring range can be extended up to 690 V AC and 1000 V DC by using the coupling unit CM-IVN. It can be configured to the requirements of the applications and therefore used multi-functional.
Pas en stock
CM-IWN.1P
The CM-IWN.1P serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems, IT AC systems with galvanically connected DC circuits, or unearthed IT DC systems with a voltage up to 400 V AC and 600 V DC. The measuring range can be extended up to 690 V AC and 1000 V DC by using the coupling unit CM-IVN. It can be configured to the requirements of the applications and therefore used multi-functional.
Pas en stock
CM-ENS.21S
The CM-ENS.21S belongs to the CM liquid level monitoring relay range. It operates with a rated control supply voltage of 24 - 240 V AC/DC and has a 1 c/o (SPDT) output with contacts rated at 250 V / 4 A. It monitors liquid levels of conductive fluids and protects pumps against dry running or tanks against overflow. The working principle as well as the sensitivity can be selected via front-face potentiometers. Several electrodes and a sealable transparent cover for protection against unauthorized changes are available as accessory. The device offers screw connection technology with double-chamber cage connection terminals.
Pas en stock
CM-IVN.S
The CM-IVN.S serves to extend the measuring range of the insulation monitoring relay CM-IWN.x for monitoring the insulation resistance up to 690 V AC and 1000 V DC in accordance with IEC 61557-8.
Pas en stock
E5CC-CX2AUM-000
Tension d'alimentation 100 à 240 V courant alternatif (CA) Contrôleur de température
74 Stock du fabricant
USA
74
CM-ENS.13S
The CM-ENS.13S belongs to the CM liquid level monitoring relay range. It operates with a rated control supply voltage of 110-130 V AC and 220-240 V AC and has a 1 c/o (SPDT) output with contacts rated at 250 V / 4 A. It monitors liquid levels of conductive fluids and protects pumps against dry running or tanks against overflow and works according to the open-circuit principle. The sensitivity can be selected via front-face potentiometers. Several electrodes and a sealable transparent cover for protection against unauthorized changes are available as accessory. The device offers screw connection technology with double-chamber cage connection terminals.
Pas en stock
CM-ENS.31S
The CM-ENS.31S belongs to the CM liquid level monitoring relay range. It operates with a rated control supply voltage of 24 - 240 V AC/DC and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A. It monitors liquid levels of conductive fluids and protects pumps against dry running or tanks against overflow. The working principle as well as the sensitivity can be selected via front-face potentiometers. Furthermore, an ON-delay or an OFF-delay can be adjusted within a range of 0.1 to 10 s. Several electrodes and a sealable transparent cover for protection against unauthorized changes are available as accessory. The device offers screw connection technology with double-chamber cage connection terminals.
Pas en stock
ADAM-4118-C
8-Ch Thermocouple Input Module
Pas en stock
CM-ENS.11P
The CM-ENS.11P belongs to the CM liquid level monitoring relay range. It operates with a rated control supply voltage of 24 - 240 V AC/DC and has a 1 c/o (SPDT) output with contacts rated at 250 V / 4 A. It monitors liquid levels of conductive fluids and protects pumps against dry running or tanks against overflow and works according to the open-circuit principle. The sensitivity can be selected via front-face potentiometers. Several electrodes and a sealable transparent cover for protection against unauthorized changes are available as accessory. The device offers maintenance free Easy Connect Technology with push-in terminals.
Pas en stock
K3HB-RNB 24VAC/VDC
24 V Courant alternatif (CA)/courant continu (CC) Tension d'alimentation Indicateur d'impulsion
7 Stock du fabricant
USA
7
2276395
Transformateur de courant enfichable, courant primaire 2500 A AC, courant secondaire 5 A AC ; classe de précision 1 ; puissance assignée 15 VA
Pas en stock
2702971
Relais de couplage enfichable SIL comme accessoire d'affichage et de saisie pour module d'interface VIP, applications de demandes élevée et faible de niveau d'intégrité de sécurité 3 Safe State Off, couple des signaux de sortie TOR au niveau du périphérique, un circuit à fermeture, un circuit report de signalisation, filtre à impulsion de test
Pas en stock
2800617
Module O/E pour système de surveillance en temps réel permettant d'acquérir et d'évaluer en permanence les coups de foudre.
Pas en stock
2901993
Huit amplificateurs-séparateurs MINI Analog Pro et convertisseurs de mesure peuvent être raccordés à un automate, à l'aide d'adaptateurs-système et de système de pré-câblage, sans câblage fastidieux et sans aucune erreur.
Pas en stock
2902425
Jeu de câbles destiné à la transmission des signaux sur le Termination Carrier pour modules de la gamme MACX Analog Ex. Raccordement des points de connexion 3.1 et 3.2 (transmission de signaux) du circuit imprimé de signalisation.
Pas en stock
2902426
Jeu de câbles destiné à la transmission des signaux et l'alimentation en tension sur le Termination Carrier pour les modules de la gamme MACX Analog Ex. Raccordement des points de connexion 3.1 et 3.2 (transmission de signaux) ainsi que des points de connexion 1.1 et 1.2 (alimentation en tension) via un connecteur PTSM à 4 pôles au circuit imprimé de signalisation.
Pas en stock
2902548
Transformateur de courant à canon, courant primaire 100 A AC, courant secondaire 5 A AC ; classe de précision 0,5 ; puissance assignée 1,5 VA
Pas en stock
2902657
Jeu de câbles destiné à la transmission des signaux et l'alimentation en tension sur le Termination Carrier pour les amplificateurs-séparateurs de la gamme MACX Analog Ex. Raccordement des points de connexion 3.2 et 2.2 (transmission de signaux avec cartes d'entrées actives) ainsi que des points de connexion 1.1 et 1.2 (alimentation en tension) du circuit imprimé de signalisation.
Pas en stock

1869 Articles