By ABB
SKU
MPN
1SAM250000R1006
The MS116-1.6 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 1.6 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
Documents
Spécifications techniques
Dimensions
Produit Largeur Net | 45 mm |
Produit Hauteur Net | 90 mm |
Produit Longueur Net | 85,6 mm |
Poids net | 0.265 kg |
Technique
Pourvoir assigné de coupure de service en court-circuit (Ics) | (230 V AC) 50 kA, (400 V AC) 50 kA, (440 V AC) 50 kA, (500 V AC) 30 kA, (690 V AC) 30 kA |
Pouvoir assigné de coupure ultime en court-circuit (Icu) | (230 V AC) 100 kA, (400 V AC) 100 kA, (440 V AC) 100 kA, (500 V AC) 100 kA, (690 V AC) 100 kA |
Courant assigné instantané de réglage de court-circuit (Ii) | 20 A |
Setting Range | 1.0 ... 1.6 A |
Puissance assignée d’emploi AC-3 (Pe) | (400 V) Three Phase 0.55 kW |
Puissance assignée d’emploi AC-3e (Pe) | (400 V) Three Phase 0.55 kW |
Tension | Circuit principal 690 V AC |
Courant nominal de fonctionnement (Ie) | 1.6 A |
Courant assignée d’emploi AC-3 (Ie) | 1.6 A |
Courant assignée d’emploi AC-3e (Ie) | 1.6 A |
Fréquence assignée (f) | Circuit principal 50 Hz, Circuit principal 60 Hz |
Tension assignée de tenue aux chocs (Uimp) | Circuit principal 6 kV |
Tension assignée d’isolement (Ui) | 690 V |
Power Loss | at Rated Operating Conditions per Pole 0.6 ... 1.7 W |
Nombre de pôles | 3 |
Courant thermique conventionnel à l’air libre (Ith) | Main Circuit 1.6 A |
Indice de protection | Housing IP20, Main Circuit Terminals IP10 |
Degré de pollution | 3 |
Electrical Durability | 100000 cycle |
Durabilite mecanique | 100000 cycle |
Type de borne | Bornes à vis |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm², Flexible 1/2x 0.75 ... 2.5 mm², Rigid 1/2x 1 ... 4 mm² |
Couple de serrage | Main Circuit 0.8 ... 1.2 N·m |
Wire Stripping Length | Main Circuit 9 mm |
Recommended Screw Driver | Pozidriv 2 |
Type d'encastrement | any; 1 ... 6 |
Montage sur rail DIN | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 400 V 0 mm, Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm, Electrical Conductive Board, Vertical 75 mm, Other Device Same Type, Horizontal 0 mm, Other Device Same Type, Vertical 150 mm |
Actuator Type | POIGNÉE ROTATIVE |
Contact Position Indication | ON / OFF |
Normes et standards | IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1 |
Technique UL/CSA
Short-Circuit Current Rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 30 kA, Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA, Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA, Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA |
Maximum Operating Voltage UL/CSA | Circuit principal 600 V AC |
Puissance nominale UL/CSA | (440 ... 480 V AC) Three Phase 0.75 Hp, (550 ... 600 V AC) Three Phase 0.75 Hp |
Full Load Amps Motor Use | (200 V AC) Three Phase 1.6 A, (208 V AC) Three Phase 1.6 A, (220 ... 240 V AC) Three Phase 1.6 A, (440 ... 480 V AC) Three Phase 1.6 A, (550 ... 600 V AC) Three Phase 1.6 A |
Locked Rotor Amps | (200 V AC) Three Phase 9.6 A, (208 V AC) Three Phase 9.6 A, (220 ... 240 V AC) Three Phase 9.6 A, (440 ... 480 V AC) Three Phase 9.6 A, (550 ... 600 V AC) Three Phase 9.6 A |
General Use Rating UL/CSA | (600 V AC) 1.6 A |
Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-12 AWG, Stranded 1/2x 16-12 AWG |
Tightening Torque UL/CSA | Main Circuit 10 in·lb |
Environnement
Température de l’air ambiant | Around the Enclosure 0 ... +40 °C, Operation -25 ... +70 °C, Operation Compensated -25 ... +55 °C, Storage -50 ... +80 °C |
Ambient Air Temperature Compensation | Oui |
Altitude de fonctionnement maximale autorisée | 2000 m |
Résistance aux chocs selon CEI 60068-2-27 | 11 ms Pulse 25g |
Resistance to Vibrations acc. to IEC 60068-2-6 | 5g / 3 ... 150 Hz |
Statut RoHS | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Pourquoi Proax pour ABB MS116-1.6?
Proax est un distributeur autorisé de ABB MS116-1.6 et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!
Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!
Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Informations complémentaires
Autres noms | MS11616 |
Taille de l'emballage | 1 |
Recommandé
- The MS116-1.6-HKF1-11 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 1.6 A and a pre-assembled front mounted auxiliary contact HKF1-11. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
- The MS116-1.0 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 1.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
- The MS116-10 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 10.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A.
- The MS116-2.5 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 2.5 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
- The MS116-0.4 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 0.40 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
- The MS116-0.63 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 0.63 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
- The MS116-12 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 12.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 25 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
- The MS116-2.5-HKF1-11 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 2.5 A and a pre-assembled front mounted auxiliary contact HKF1-11. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
- The MS116-0.25 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 0.25 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
- The MS116-0.16 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 0.16 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
- The MS116-20 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 20.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 10 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
- The MS116-20-HKF1-11 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 20.0 A and a pre-assembled front mounted auxiliary contact HKF1-11. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 10 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
- The MS116-25 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 25.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 10 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.