AF12-30-10-13

By ABB

ABBAF12301013
ABBDistributeur Officiel
The AF12-30-10-13 is a 3 pole - 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 5.5 kW / 400 V AC (AC-3) or 7-1/2 hp / 480 V UL and switching power circuits up to 28 A (AC-1) or 28 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Spécifications techniques

Dimensions

Produit Largeur Net45 mm
Produit Longueur Net77 mm
Produit Hauteur Net86 mm
Poids net0,27 kg

Technique

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC0
Normes et standardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-16, UL 60947-4-1, CSA C22.2 No. 60947-4-1
TensionCircuit auxiliaire 690 V, Circuit principal 690 V
Fréquence assignée (f)Circuit auxiliaire 50 / 60 Hz, Circuit principal 50 / 60 Hz
Courant thermique conventionnel à l’air libre (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 35 A, acc. to IEC 60947-5-1, q = 40 °C 16 A
Courant assignée d’emploi AC-1 (Ie)(690 V) 40 °C 28 A, (690 V) 60 °C 28 A, (690 V) 70 °C 24 A
Courant assignée d’emploi AC-3 (Ie)(415 V) 60 °C 12 A, (440 V) 60 °C 12 A, (500 V) 60 °C 12.5 A, (690 V) 60 °C 9 A, (380 / 400 V) 60 °C 12 A, (220 / 230 / 240 V) 60 °C 12 A
Courant assignée d’emploi AC-3e (Ie)(415 V) 60 °C 12 A, (440 V) 60 °C 12 A, (500 V) 60 °C 12.5 A, (690 V) 60 °C 9 A, (380 / 400 V) 60 °C 12 A, (220 / 230 / 240 V) 60 °C 12 A
Puissance assignée d’emploi AC-3 (Pe)(400 V) 5.5 kW, (415 V) 5.5 kW, (440 V) 5.5 kW, (500 V) 7.5 kW, (690 V) 7.5 kW, (380 / 400 V) 5.5 kW, (220 / 230 / 240 V) 3 kW
Puissance assignée d’emploi AC-3e (Pe)(415 V) 5.5 kW, (440 V) 5.5 kW, (500 V) 7.5 kW, (690 V) 7.5 kW, (380 / 400 V) 5.5 kW, (220 / 230 / 240 V) 3 kW
Courant assignée d’emploi AC-15 (Ie)(500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (400 / 440 V) 3 A
Courant assigné de courte durée admissible (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A, for 0.1 s 140 A, for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-2 / AC-4) 300 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour
Courant assignée d’emploi DC-13 (Ie)(24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.27 A / 60 W, (250 V) 0.27 A / 68 W, (400 V) 0.15 A / 60 W, (500 V) 0.13 A / 65 W, (600 V) 0.1 A / 60 W
Tension assignée d’isolement (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V, acc. to UL/CSA 600 V
Tension assignée de tenue aux chocs (Uimp)6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V, 60 Hz 100 ... 250 V, DC Operation 100 ... 250 V
Durée de fonctionnement nominaleEntre la mise hors tension de la bobine et la fermeture du contact NC (normally closed) 13 ... 98 ms, Entre la mise hors tension de la bobine et l'ouverture du contact NO (normally open) 11 ... 95 ms, Entre la mise sous tension de la bobine et l'ouverture du contact NC 38 ... 90 ms, Entre la mise sous tension de la bobine et la fermeture du contact NO 40 ... 95 ms
Montage sur rail DINTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)2 x M4 screws placed diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm², Flexible with Insulated Ferrule 1x 0.75 ... 4 mm², Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm², Rigid 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm, Control Circuit 10 mm, Main Circuit 10 mm
Indice de protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Type de borneBornes à vis

Technique UL/CSA

NEMA Size0
Continuous Current Rating NEMA18 A
Horsepower Rating NEMA(115 V AC) Single Phase 1 Hp, (200 V AC) Three Phase 3 Hp, (230 V AC) Single Phase 2 Hp, (230 V AC) Three Phase 3 Hp, (460 V AC) Three Phase 5 Hp, (575 V AC) Three Phase 5 Hp
General Use Rating UL/CSA(600 V AC) 28 A
Puissance nominale UL/CSA(120 V AC) Single Phase 1 hp, (200 ... 208 V AC) Three Phase 3 hp, (220 ... 240 V AC) Three Phase 3 hp, (240 V AC) Single Phase 2 hp, (440 ... 480 V AC) Three Phase 7-1/2 hp, (550 ... 600 V AC) Three Phase 10 hp
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb, Control Circuit 11 in·lb, Main Circuit 13 in·lb

Environnement

Température de l’air ambiantClose to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Altitude de fonctionnement maximale autoriséeWithout Derating 3000 m
Resistance to Vibrations acc. to IEC 60068-2-65 ... 300 Hz 4 g closed position / 2 g open position
Résistance aux chocs selon CEI 60068-2-27Closed, Shock Direction: B1 25 g, Open, Shock Direction: B1 5 g, Shock Direction: A 30 g, Shock Direction: B2 15 g, Shock Direction: C1 25 g, Shock Direction: C2 25 g
Statut RoHSFollowing EU Directive 2011/65/EU

Pourquoi Proax pour ABB AF12-30-10-13?

Proax est un distributeur autorisé de ABB AF12-30-10-13 et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!

Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!

Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Recommandé

Demande de délai de livraison